Zhenling Metal has outlined how buyers of machined aluminum parts can specify anodizing services so that a part which passed machining inspection still fits after finishing. The guidance draws on the company's published anodizing and milling pages and on technical material from the Aluminum Anodizers Council. It targets a familiar failure: a bore, thread or mating fit that measured correctly before finishing and binds afterward.

No new finishing line, capacity figure or test data is announced. Capability and timing are treated as provisional on Zhenling's anodizing page until a drawing and a finish callout have been reviewed, and this release keeps to that position.

What Anodizing Does to the Surface of an Aluminum Part

Anodizing is not a layer of paint resting on top of the metal, and buyers comparing anodizing services for machined parts start from that difference. Zhenling Metal's anodizing page describes an aluminum oxide layer that grows from the base metal during an electrochemical process. For that reason, alloy condition, pretreatment, electrical contact, masking, coating growth and sealing decisions all reach the fit, appearance and corrosion resistance of the finished part.

In its published FAQ, the Aluminum Anodizers Council puts the geometry plainly. Oxide is thicker than the aluminum it consumes, so the part changes size. Under nominal Type II conditions the rule of thumb is two-thirds in and one-third out. Under hard coat, or Type III, conditions the split becomes half in and half out.

Where It Stops: A rule of thumb describes nominal conditions. Temperature, current density, alloy, etching and brightening all shift the result, according to the council, and different anodizers run slightly different parameters. A drawing works better when it states the final dimension the buyer needs instead of a buildup the buyer has guessed.

Type II, Type III and the MIL-PRF-8625 Framework

MIL-PRF-8625 is the specification Zhenling's page uses to frame an anodizing callout. Citing the council's overview, the page notes that this specification defines six coating Types and two Classes: Type II is sulfuric, Type III is hard, Class 1 is non-dyed and Class 2 is dyed. A callout that names only the Type leaves the Class, the thickness and the seal open.

Thickness separates the two common routes far more than the names suggest. In the council's Anodizing Reference Guide, Type II coatings from a sulfuric acid bath are listed at 1.8 to 25.4 microns, and Type III hard coat at 12.7 to 115 microns. Moving a part from Type II to Type III is therefore a dimensional change, not merely a harder surface.

Production release needs more than the label. On Zhenling's page, the Type, the class, the thickness, the appearance and the acceptance evidence are separate decisions, and the named specification with its current revision is requested whenever one governs the part.

How Much a Bore or a Thread Actually Moves

Unit conversion is the first trap. For that step, Zhenling's page gives the working figure: 1 mil equals 0.001 inch, approximately 25 μm. It adds that this is a unit conversion rather than the company's default range. Specifications written in mils and drawings dimensioned in millimeters meet on exactly that line, which is where small errors slip through.

Holes are the sensitive feature. A hole has two sides, so the outward growth counts twice across its diameter. Two worked examples in the council's FAQ show the effect:

Coating in the exampleOutward growth per surfaceReduction in hole diameter Type II, 0.6 milOne-third of 0.6 mil0.4 mil Type III, 1.5 milOne-half of 1.5 mil1.5 mil Read through the 25 μm conversion, the Type III example takes roughly 38 μm off a bore diameter. On a bearing seat or a locating hole, a change of that size can move the part into a different fit. Zhenling's page draws the line clearly, though: the conversion helps a buyer read a specification, but it isn't a basis for a universal buildup allowance. That allowance belongs in the quote review for the specific alloy and route, and it is one of the first lines to compare when quotations for anodizing services arrive from different shops.

Class 1 and Class 2 Versus Class I and Class II

A persistent confusion in anodizing callouts comes from two unrelated uses of the word class. Under MIL-PRF-8625, as Zhenling's page summarizes it, Class 1 means non-dyed and Class 2 means dyed. Nothing in that pair says anything about thickness.

A different pair appears in the council's FAQ. Class I and Class II architectural coatings come from the Aluminum Association, with a minimum coating thickness of 0.7 mil (18 microns) for Class I and 0.4 mil (10 microns) for Class II. The council adds that these classes should not be confused with Type I, Type II and Type III coatings.

Where it Stops: guessing intent. A bare note reading Class II on a machined bracket can be taken as an architectural thickness floor by one finisher and as a dyed military finish by another. The fix is to name the governing specification and revision next to the Type and Class, state whether the part is dyed, and give the required thickness with its tolerance.

Alloy and Temper: Decide What the Finish Can Do

Most aluminum alloys will build oxide in the tank, but not equally well. The council's FAQ names the copper-containing 2000 series as generally the most difficult to anodize and the 5000 and 6000 series as the easiest.

For hard coat, the council's reference guide is more specific. Alloy 2011 is listed as not recommended for Type III. Alloy 2024 carries a generally accepted maximum thickness of 0.0015 inch, 6061 reaches 0.003 inch and 7075 reaches 0.004 inch. Switching a part from 6061 to 2024 for machinability also halves the hard coat thickness available to it.

Zhenling Metal's milling page turns this into a request line for aluminum alloy parts: define temper, grain-direction concern, cosmetic surface, anodizing allowance and thin-wall distortion risk. Each item changes how the part is machined long before it reaches the anodizing tank, and its anodizing page adds that a finish approved on one material condition is not automatically a color or texture standard for another.

Masking, Racking and the Risk of a Contact Mark

Anodizing passes an electrical current through the part, so every piece has to be held by an electrical contact. Zhenling's page is direct about the consequence: a required electrical contact point can leave a visible mark, and its acceptable location must be selected before cosmetic acceptance is fixed. Masks and plugs need the same early decision, so the company's dimension-at-risk track asks buyers to mark these features on the drawing:

  • Internal and external threads, with the mask, plug or post-finish strategy.
  • Precision bores, with diameter, depth and the stage at which each is measured.
  • Mating fits, meaning shafts, pockets and locating faces, and which interface receives coating.
  • Sealing faces, including gasket, O-ring and fluid-contact lands, with mask limits and edge transitions.
  • Electrical contacts, meaning grounding areas and bare-metal zones that must stay exposed.
  • Cosmetic faces, with primary viewing surfaces, grain, texture, color and rack restrictions.

The council's FAQ adds a practical boundary. Holes and bores can usually be masked without too much difficulty, while flat areas can sometimes be more difficult to mask.

Where it Stops: masking keeps coating off a surface; it does not give back a dimension that has already grown. If a thread is left unmasked and its fit is lost, the remedy is rework or a new part, not a looser gauge.

Color Acceptance Needs More Than a Color Name

Black anodized aluminum, clear anodized aluminum and other colors shouldn't be purchased by a color name alone, according to Zhenling's page. Acceptance needs a reference, viewing conditions, allowed variation and a rule for comparing one batch with the next. Pretreatment counts too, because mechanical lines, etch response, weld zones and earlier handling can stay visible under the finish.

Why is a name not enough? Dye intensity, the council explains, is related to the thickness of the anodic film, the dye concentration, immersion time and temperature, and color has at least three dimensions rather than a single light-to-dark scale. Two lots ordered under the same color name can therefore still differ.

A physical sample on the same alloy and pretreatment, with the judged surfaces named, gives both sides something to measure against. Zhenling's page asks for one when it is available.

About Zhenling Metal (Shanghai Zhenling Metal Co., Ltd.)

Shanghai Zhenling Metal Co., Ltd., founded in 2006, supplies custom metal parts made to customer drawings, with a commercial office in Shanghai and a manufacturing plant in Jiashan, Zhejiang. Its published service pages cover CNC milling, CNC turning and surface finishing, including anodizing for aluminum parts, with the finishing route, responsibility and processing site confirmed in each written quotation.

Buyers preparing an aluminum part with an anodizing callout can review Zhenling Metal's machining and surface finishing services and send the drawing and finish specification to ting.liang@zhenlingmetal.com, the export sales address on the company's contact page.



Contact
Ting Liang
Shanghai Zhenling Metal Co., Ltd.
ting.liang@zhenlingmetal.com
+86 139 1603 6822


Disclaimer. This is a paid press release.